久久国产精品九九国产精品_国产精品欧美日韩中字一区二区_在线免费黄色网址_国产深夜福利在线观看网站_18禁秘 啪啪污污网_日韩在线一区二区三区视频_国产农村乱对白刺激视频亚洲性爱在线_蜜臀AV中文无码字幕色三_国产日韩欧美午夜片_人人公开免费超级碰碰碰视频

Hanging HFC-227ea Gas Fire Exting…

Home > Products > Hanging HFC-227ea Gas Fire Exting…

Hanging HFC-227ea Gas Fire Extinguishing Devices

Back

Product Overview

Product Description:

Hanging HFC-227ea Gas Fire Extinguishing Devices devided by the way of starting: 

1.Temperature susceptibilitystarting type: consist oftemperature sensing head、pressure gage、container、hanging bracket, etc. When the temperature of protection zone reaches the blastingtemperature of thermal glass ball which will blast…

(If you are interested in our products, please click to view contact details)

Share:
  • Introduction
  • Download

Product Description:

Hanging HFC-227ea Gas Fire Extinguishing Devices devided by the way of starting: 

1.Temperature susceptibilitystarting type: consist oftemperature sensing head、pressure gage、container、hanging bracket, etc. When the temperature of protection zone reaches the blastingtemperature of thermal glass ball which will blaste so as to start the fireextinguishing device and release the agent.

2.Electromagnetic starting type: consist of container valve、pressure gage、container、electromagnetic driving device、pressuresignal feedback device、nozzle、hanging bracket、fire alarm controller、heat and smoke detector, etc. When a fire breaks out, heat and smoke detector will transmitsignals to fire alarm controller which will then control electromagneticdriving device to open container valve, release agent and finally put out thefire. It can be singly used as well as combined by two ormore.

3.Temperaturesensing electric starting type:combinedby temperature susceptibility starting type and electromagnetic starting type. Consist of containervalve、pressure gage、container、electromagnetic driving device、pressure signal feedback device、hanging bracket、fire alarm controller、heat and smoke detector, etc. Theworking principle is almost the same as Electromagnetic starting type. It canbe singly used as well as combined by two or more. As it is a combined fireextinguishing device, it is more stable to actuate.

Performance parameters:

Technical characteristics:
1.Electromagnetic starting type and Temperaturesensing electric starting type can be used seprately as well as jointly;

2.Both Electromagnetic starting type and Temperature sensing electricstarting type have Automatic fire alarm systemwhich can be automatically start or manually start with high safty.

3.BothElectromagnetic starting type and Temperature sensing electric starting typehave pressure signal feedback device and can implementate 24H monitoring. 

4.Temperaturesensing electric starting type is consisted of temperature susceptibilitystarting type and electromagnetic starting type.The combinationmakes fire extinguishing devices more stable.

5.Temperaturesensing electric starting type can install LiLou network monitoring equipment,thus realize the network monitoring of remote protection zone.

Places for Application

Cabletunnels, cable interlayer, computer room, generator room, archives (warehouse),transformer room, communication base station, dangerous goods warehouse, andother industrial and civil areas.

Compilation Basis

GA 13—2006 <Hanging gas fire extinguishing system>

Specification andModel 

  • Case Introduction